Products

  • CS1528C RS485 PH Sensor Output Industry Online Hydrofluoric acid PH electrode

    CS1528C RS485 PH Sensor Output Industry Online Hydrofluoric acid PH electrode

    Sensor hydrofluoric acid environment
    digitales pH sensores tecLine electrodes sunt qualitates sensores pro applicationibus professionalibus in processu et technologia mensurae industrialis.Hae electrodes notae sunt pro usu materiae et componentium qualitatis.Electrodes compositi ordinantur (electrode vitreo vel metallo et relatio electrode in uno stipite componuntur).Temperatus probe etiam integrari potest ut optio, secundum rationem.pH electrode industrialis est electrode cost-efficax a societate nostra evoluta pro variis aquae vastae industriae, purgamentorum domesticarum, aquae magnae potandi et curationis aquae environmentalis.
  • CS1500C/CS1501C Digital PH Electrode sensorem 4-20mA RS485 Aquae qualitatis

    CS1500C/CS1501C Digital PH Electrode sensorem 4-20mA RS485 Aquae qualitatis

    Designed For pH sensorem common water quality.
    sensorem digitalpH est aptum qualitati aquae communi., cum duplici consilio pontis salis, duplicata aqua emissarii interfaciei, et resistentia ad emissam mediae partis adversam.Porus ceramicus e parametro electrode interfaciei manat, quod non facile obstruetur, et magnae aquae qualitates instrumentorum circumscriptionum communis aptus est.Cape PTFE magnum anulum diaphragma ut firmitatem electrode curare; applicationis industriae: sustentans Pro solutionibus chemicis generalibus purgamentorum industriae PH sensorem specialem adhibet membranam vitream sensitivam.Jejunium responsio et summa stabilitas.In pH magna curatione aquae, vigilantia hydrological, curatio aquae vastae, lacus natandi, piscinae pisces et fertilizers, oeconomiae et biologiae usus est.
  • CS2733C RS485 Industrial Online ORP PH Controller Meter For Water Measurement

    CS2733C RS485 Industrial Online ORP PH Controller Meter For Water Measurement

    Designed For general chemical solutions
    digital ORP sensor aptus est ad processuum industrialium generalem, cum duplici consilio pontis salsi, duplicata aqua emissarii interfaciei, et resistentia ad emissationem mediae adversae.Porus ceramicus e parametro electrode interfaciei manat, quod non facile obstruetur, et magnae aquae qualitates instrumentorum circumscriptionum communis aptus est.Cape PTFE magna anulum diaphragmate ut diuturnitatem electrode; Application industria: supporting quia generalis solutiones chemical
  • CS2745C/CS2745CT Professio Portable pH/ORP Meter Water Quality High Temperature orp electrical

    CS2745C/CS2745CT Professio Portable pH/ORP Meter Water Quality High Temperature orp electrical

    Designed For High temperatus environment
    electrode digitalis ORP solidam dielectricam in mundo antecedens et amplam PTFE commissuram liquidam induit.Haud faciles intercludere, facile ponere.Longum intervallum relatio diffusionis semita valde prorogat servitium vitae electro in asperis ambitibus.Cum sensori temperato constructo (Pt100, Pt1000, etc. eligi potest secundum usorum requisita) et amplitudine temperatus, in locis explosionis probationis adhiberi potest.
  • CS2753C orp electrical tds conductivity probe probatoris sensorem monitor electrode Pro generalibus solutionibus chemicis

    CS2753C orp electrical tds conductivity probe probatoris sensorem monitor electrode Pro generalibus solutionibus chemicis

    Designed For general chemical solutions
    digital ORP sensor aptus est ad processuum industrialium generalem, cum duplici consilio pontis salsi, duplicata aqua emissarii interfaciei, et resistentia ad emissationem mediae adversae.Porus ceramicus e parametro electrode interfaciei manat, quod non facile obstruetur, et magnae aquae qualitates instrumentorum circumscriptionum communis aptus est.Cape PTFE magna anulum diaphragmate ut diuturnitatem electrode; Application industria: supporting quia generalis solutiones chemical
  • CS2705C/CS2705CT ORP Electrode electrodwith Temperature et 3/4" Pipe ORP PH Controller

    CS2705C/CS2705CT ORP Electrode electrodwith Temperature et 3/4" Pipe ORP PH Controller

    Sodium hypochlorite ad solutionem destinata.
    Magnae bulbi sentiendi facultatem augent ad sentiendi consectetuer iones, et bene operantur in ambitu complexu. Electrode materialis PP magnum habet repugnantiam, vires mechanicas et duritias, resistentiam variis solventibus organicis et acidis et alcali corrosionibus.
    Fortis anti-impedimenti facultatem, altam stabilitatem et longam transmissionis distantiam.Nullam venenatis eget elit.
  • CS2703C/CS2703C Orp Ph Meter chloride ions Industrial Hydroponic Orp Ph Controller

    CS2703C/CS2703C Orp Ph Meter chloride ions Industrial Hydroponic Orp Ph Controller

    Gravia metalla disposita.
    Longum intervallum relatio diffusionis semita valde prorogat servitium vitae electro in asperis ambitibus.Novus bulbus vitreus designatus aream bulbi auget, generationem prohibet
    bullas impeditas in quiddam internae, et certius facit mensuram. Electrode cinematographico vitreo-sensitivo fit immediatio, et etiam notas habet responsionis celeritatis, mensurae accuratae, stabilitatis bonae, et non facile hydrolyze in causa humilis conductivity et aquae puritatis.
  • CS2701C ORP PH Controller Meter For Water Measurement Environment ORP Electrode

    CS2701C ORP PH Controller Meter For Water Measurement Environment ORP Electrode

    General application disposita.
    Pons salis duplicatus designatur, duplex emissarium emissarium interfaciei emissarium, mediae emissae e contrario resistens.
    Porus ceramicus parametri electrode ex interface manat et non facile obstruetur, quod aptum est ad vigilantiam instrumentorum communicationis aquae communis.
    Summus vis bulbi vitrei designatio, species vitreae fortior est. Electrode sonum funestum humilem adoptat, signum output longius et firmius est.
    Magnae bulbi sentiendi facultatem augent hydrogenii iones sentiendi, et bene in aqua communi instrumentorum qualitatum environment.
  • CS2700C RS485 Industrial Online ORP PH Controller Meter For Water Measurement

    CS2700C RS485 Industrial Online ORP PH Controller Meter For Water Measurement

    General application disposita.
    Pons salis duplicatus designatur, duplex emissarium emissarium interfaciei emissarium, mediae emissae e contrario resistens.
    Porus ceramicus parametri electrode ex interface manat et non facile obstruetur, quod aptum est ad vigilantiam instrumentorum communicationis aquae communis.
    Summus vis bulbi vitrei designatio, species vitreae fortior est. Electrode sonum funestum humilem adoptat, signum output longius et firmius est.
    Magnae bulbi sentiendi facultatem augent hydrogenii iones sentiendi, et bene in aqua communi instrumentorum qualitatum environment.
  • CS2543C/CS2543CT ORP Meter Monitoring Controller Online PH Meter

    CS2543C/CS2543CT ORP Meter Monitoring Controller Online PH Meter

    General application disposita.
    Pons salis duplicatus designatur, duplex emissarium emissarium interfaciei emissarium, mediae emissae e contrario resistens.
    Porus ceramicus parametri electrode ex interface manat et non facile obstruetur, quod aptum est ad vigilantiam instrumentorum communicationis aquae communis.
    Summus vis bulbi vitrei designatio, species vitreae fortior est. Electrode sonum funestum humilem adoptat, signum output longius et firmius est.
    Magnae bulbi sentiendi facultatem augent hydrogenii iones sentiendi, et bene in aqua communi instrumentorum qualitatum environment.
  • CS2505C/CS2505CT ORP Meter High Quality Digital pH/ORP Tester TDS / Salinity / Resistivity Meter

    CS2505C/CS2505CT ORP Meter High Quality Digital pH/ORP Tester TDS / Salinity / Resistivity Meter

    Sodium hypochlorite ad solutionem destinata.
    Praeclara applicatio pH electrodis in aquae marinae pH mensurationis.
    1. Soliditatis liquidae coniunctae consilio: Electrodae relatio systematis non porosum, solidum, non-commutationem systematis referentis est.Omnino vitare varias difficultates per commercium et obstructiones liquidae commissurae causatae, sicut relatio electrode facile est inquinari, relatio vulcanizationis veneficii, relationis amissi et aliorum problematum.
    2. Materia anti-corrosio: In aqua marinis valde corrosis, CS2505C/CS2505CT pH electrode ex titanii marino facta est materia stannum ad stabilitatem electrode perficiendam.

  • CS2503C/CS2503CT Orp Controller Multiparameter Meter High Quality Tester

    CS2503C/CS2503CT Orp Controller Multiparameter Meter High Quality Tester

    Disposito marinis environment.
    Praeclara applicatio pH electrodis in aquae marinae pH mensurationis.
    1. Soliditatis liquidae coniunctae consilio: Electrodae relatio systematis non porosum, solidum, non-commutationem systematis referentis est.Omnino vitare varias difficultates per commercium et obstructiones liquidae commissurae causatae, sicut relatio electrode facile est inquinari, relatio vulcanizationis veneficii, relationis amissi et aliorum problematum.
    2. Materia anti-corrosio: In aqua marinis valde corrosis, CS2503C/CS2503CT pH electrode ex titanii marino facta est materia stannum ad stabilitatem electrode perficiendam.