Online Membrane Residual Chlorine Meter T4055

Brevis descriptio:

Online residua chlorine metri microprocessoris substructio aquae qualitatem instrumenti instrumenti moderandi magna online.


Product Detail

Product Tags

Online Membrane Residual Chlorine Meter T4055

T4055
4000-A
4000-B
Munus

Online residua chlorine metri microprocessoris substructio aquae qualitatem instrumenti instrumenti moderandi magna online.

Typical Usus

Hoc instrumentum late in magna copia aquae adhibita est, aqua sonum, aqua rustica bibens, aqua circulens, aqua cinematographica lavans, aqua disinfectant, aqua piscinae. aliisque processibus industrialibus. Continua vigilantia et moderatio chlorini residualis, pH et quantitatis temperatae in solutione aquea.

Mains Supple

85~ 265VAC±10%,50±1Hz, potentia ≤3W;
9~36VDC, potestas consumption≤3W;

Mensuratio dolor

CHLORUM RELICTUM: 0~20ppm; 0~20mg/L;
pH: -2~16pH;
Temperature: 0~150℃.

Online Membrane Residual Chlorine Meter T4055

1

Modus mensurae

1

Calibration Modus

3

Ager Calibration

4

Modus occasu

Features

1.Large ostensio, vexillum 485 communicationis, cum terrore online and offline, 98*98*130mm metri size, 92.5*92.5mm magnitudinum foraminis, 3.0 inch amplum tegumentum ostentum.

2. Data curva recordatio munus inauguratum est, apparatus metrum manualem legendi substituit, et quaestionis ambitus ad libitum specificatur, ita ut notitia non amplius amittatur.

3. Instructa in variis mensuris functionibus, una machina cum multiplicibus functionibus, occurrens requisitis variarum mensurarum signa.

4. Consilium totius machinae est IMPERVIUS et dustproof, et tegumento posteriori connexionis terminatio additur ad vitam servitutis in asperis ambitibus amplificandam.

5.Panel/murus/tibiae institutionem, tres optiones praesto sunt ad varias institutiones industriae situs requisita.

Connexiones electricae

Electrical connexio Connexio inter instrumentum et sensorem: potestas copia, signum output, contactus terror publicus et nexus inter sensorem et instrumentum omnes intus instrumenti sunt. Longitudo filum plumbeum pro electrode fixo fere 5-10 metrorum est, et titulus seu color respondentis in sensorem Insert filum in terminale intra instrumentum respondente et obstringito.

Instrumentum institutionem modum

a2

Specificationes technicae

Mensurae range 0.005~20.00mg/L ; 0.005~20.00ppm
Unitas mensurae Membrana
Resolution 0.001mg/L ; 0.001ppm
basic error

±1%FS

։

Mensurae range -2 16.00pH
Unitas mensurae pH
Resolution 0.001pH
basic error ±0.01pH

. ˫

Temperature -10 150.0 (Ex sensorem)

˫

Temperature Resolution 0.1

˫

Temperature Basic error ±0.3

։

Current output 2 circulos: 4 20mA
Signum output RS485 Modbus RTU
Alia munera Data record
Tres contactus imperium Nullam 2 circulos: 5A 250VAC,5A 30VDC
Ad libitum potestatem copia 85~265VAC,9~36VDC, potentia consumption≤3W
Opus conditionibus Nullus fortis campus magneticus intercedit circa campum geomagneticum nisi.

. ˫

opus temperatus -10 60
Relativum humiditas ≤90%
IMPERVIUS rating IP65
Pondus 0.6kg
Dimensiones 98×98×130mm
Installation ostium magnitudine 92.5×92.5mm
Modi institutionem Panel & murum conscendit vel pipeline

CS5763 Residual Chlorine Sensor (Membrane)

b1

Exemplar No.

CS5763

Modus mensurae

Membrana

Praesent materia

POM+316L

IMPERVIUS gradus

IP68

Mensurae range

0 - 20.00 mg/L

Sagaciter

±0.05mg/L;

Pressura resistentia

≤0.3Mpa

Temperatus compensatio

NTC10K

Temperatus range

0-50℃

Calibration

Chlorum libero aqua, aquae specimen calibratiis

Connexio modi

4 core funem

Cable longitudo

Vexillum 5m cable, ad 100m . extendi potest

Installation thread

NPT3/4''

Applicationem

Ictu aqua disinfectant humorem, etc.

 


  • Previous:
  • Next:

  • Epistulam tuam hic scribe et mitte nobis