Online Conductivity / Resistivity / TDS / Salinity Meter T6530
Oxygeni dissoluta est: 0~40mg/L, 0~400%;
Vestibulum rhoncus mensurae, quae in ppm unitate monstratur.
Online Dissolved Oxygen Meter T4046
Modus mensurae
Calibration modus
Modus occasu
1.Large ostentatio, vexillum 485 communicationis, cum terrore online and offline, 98*98*130 metrorum magnitudo, 92.5*92.5 foraminis magnitudo, 3.0 inch magnae screen ostentus.
2.Fluorescent electrodis dissoluti oxygenii principium physicam opticam adoptat, nullum chemicum reactionem in mensuratione, nullam influentiam bullarum, piscinae aerationis anaerobicae institutionem et mensurationem stabiliorem, liberam postea conservationem, et usui commodiorem.
3. Materias diligenter elige et unumquodque ambitum componentem stricte eligat, qui stabilitatem gyrationis diuturnae operationis valde melioret.
4. Nova inductio suffocat virtutis tabulae impressionem electromagneticorum interventus efficaciter minuere potest, et notitia stabilior est.
5. Consilium totius machinae est IMPERVIUS et dustproof, et tegumento posteriori connexionis terminatio additur ad vitam servitutis in asperis ambitibus amplificandam.
6.Panel/murus/tibiae institutionem, tres optiones praesto sunt ad varias institutiones industriae site requisita.
Mensurae range | 0~40.00mg/L; 0~400.0% |
Unitas mensurae | mg/L; % |
Resolution | 0.01mg/L; 0.1% |
basic error | ±1%FS |
Temperature | -10~150℃ |
Temperature Resolution | 0.1℃ |
Temperature Basic error | ±0.3℃ |
Current output | 4~ 20mA, 20~4mA, (resistentia onus <750Ω) |
Communication output | RS485 MODBUS RTU |
Nullam potestatem contactus | 5A 240VAC,5A 28VDC vel 120VAC . |
Virtus copia (libitum) | 85~265VAC,9~36VDC, potentia consumption≤3W |
Opus conditionibus | Nullus fortis campus magneticus intercedit circa campum geomagneticum nisi. |
opus temperatus | -10~60℃ |
Relativum humiditas | ≤90% |
IP rate | IP65 |
Instrumentum Pondus | 0.6kg |
Instrumentum Dimensiones | 98×98×130mm |
Adscendens foraminis dimensiones | 92.5*92.5mm |
Modi institutionem | Panel, Wall mounted, pipeline |
Digital Dissolvere Oxygen Sensor
Exemplar No. | CS4760D |
Virtus / Output | 9~36VDC/RS485 MODBUS RTU |
Modus mensuræ | Modus Fluorescens |
habitationi Material | POM+316LStainless steel |
IMPERVIUS Rating | IP68 |
Mensuratio dolor | 0-20mg/L |
Sagaciter | ±1%FS |
Pressura dolor | ≤0.3Mpa |
TemperatureCompensation | NTC10K |
Temperatus dolor | 0-50℃ |
Calibration | Aqua Anaerobic Calibration et Aeris Calibration |
Connection Methodi | 4 core funem |
Cable Longitudo | Vexillum 10m cable, extendi potest |
Installation Thread | G3/4'' |
Applicationem | General applicatione, flumen, lacus, aqua potus, tutela ambitus, etc |