Online Chlorine Dioxide Meter T4053
Metrum dioxidum chlorinum Online microprocessor-substructum aqua qualitas instrumenti instrumenti magnae dicionis.
Typical Usus
Hoc instrumentum late in magna copia aquae adhibita est, aqua sonum, aqua rustica bibens, aqua circulens, aqua cinematographica lavans, aqua disinfectant, aqua piscinae. aliisque processibus industrialibus. Continua vigilantia et moderatio dioxidis et temperaturae chlorine in solutione aquea valet.
Mains Supple
85~ 265VAC±10%,50±1Hz, potentia ≤3W;
9~36VDC, potestas consumption≤3W;
Mensuratio dolor
Chlorine dioxide: 0~20mg/L; 0~20ppm;
Temperature: 0~150℃.
Online Chlorine Dioxide Meter T4053
Modus mensurae
Calibration Modus
Ager Calibration
Modus occasu
Features
1.Large ostensio, vexillum 485 communicationis, cum terrore online and offline, 98*98* 130mm metri size, 92.5*92.5mm foraminis amplitudinis, 3.0 inch amplum tegumentum ostentum.
2.Historica curva: Data mensurae dioxidae chlorine singulae 5 minutae automatice condi possunt, et residua valor chlorini continue per unum mensem condi potest. Vexillum solutionem praebere calibrationis et campi calibrationis.
3. Instructa in variis mensuris functionibus, una machina cum multiplicibus functionibus, occurrens requisitis variarum mensurarum signa.
4. Consilium totius machinae est IMPERVIUS et dustproof, et tegumento posteriori connexionis terminatio additur ad vitam servitutis in asperis ambitibus amplificandam.
5.Panel/murus/tibiae institutionem, tres optiones praesto sunt ad varias institutiones industriae situs requisita.
Connexiones electricae
Electrical connexio Connexio inter instrumentum et sensorem: potestas copia, signum output, contactus terror publicus et nexus inter sensorem et instrumentum omnes intus instrumenti sunt. Longitudo filum plumbeum pro electrode fixo fere 5-10 metrorum est, et titulus seu color respondentis in sensorem Insert filum in terminale intra instrumentum respondente et obstringito.
Instrumentum institutionem modum
Specificationes technicae
Mensurae range | 0.005~20.00mg/L ; 0.005~20.00ppm |
Unitas mensurae | Potentiometrica methodus |
Resolution | 0.001mg/L ; 0.001ppm |
basic error | ±1%FS . ˫ |
Temperature | -10 150.0 (Ex sensorem) ˫ |
Temperature Resolution | 0.1 ˫ |
Temperature Basic error | ±0.3 ։ |
Current output | 2 circulos: 4 20mA |
Signum output | RS485 Modbus RTU |
Alia munera | Data recordum & curva ostentationem |
Tres contactus imperium Nullam | 2 circulos: 5A 250VAC,5A 30VDC |
Ad libitum potestatem copia | 85~265VAC,9~36VDC, potentia consumption≤3W |
Opus conditionibus | Nullus fortis campus magneticus intercedit circa campum geomagneticum nisi. . ˫ |
opus temperatus | -10 60 |
Relativum humiditas | ≤90% |
IMPERVIUS rating | IP65 |
Pondus | 0.6kg |
Dimensiones | 98×98×130mm |
Installation ostium magnitudine | 92.5×92.5mm |
Modi institutionem | Panel & murum conscendit vel pipeline |
CS5560 Chlorine Dioxide Sensor
Exemplar No. | CS5560 |
Modus mensurae | Tri-electrode methodo |
Metire materia | Duplex liquida commissura, angularis liquida commissura |
Praesent materia / Dimensiones | PP, Glass, 120mm*Φ12.7mm |
IMPERVIUS gradus | IP68 |
Mensurae range | 0 - 5.000 mg/L, 0 - 20.00 mg/L |
Sagaciter | ±0.05mg/L; |
Pressura resistentia | ≤0.3Mpa |
Temperatus compensatio | Nulla vel Mos NTC10K |
Temperatus range | 0-50℃ |
Calibration | Sample calibration |
Connexio modi | 4 core funem |
Cable longitudo | Vexillum 5m cable, ad 100m . extendi potest |
Installation thread | PG13.5 |
Applicationem | Ictu aqua disinfectant humorem, etc. |